AS/NZS 2589:2017 Gypsum linings - Application and finishing
Standards Australia/Standards New Zealand
Supersedes: AS/NZS 2589:2007 Gypsum linings - Application and finishing
Draft Designation: DR AS/NZS 2589:2016Amended by: AS/NZS 2589:2017 Amd 1:2018 Gypsum linings - Application and finishing
Amended by: AS/NZS 2589:2017 Amd 2:2021 Gypsum linings - Application and finishing
This Standard was prepared by the Joint Standards Australia/Standards New Zealand Committee BD-011, Interior Board Lining, to supersede AS/NZS 2589:2007, Gypsum linings—Application and finishing.
This Standard incorporates Amendment No. 1 (November 2018) and Amendment No. 2 (April 2021). The changes required by the Amendment are indicated in the text by a marginal bar and amendment number against the clause, note, table, figure or part thereof affected.
The objective of this Standard is to provide manufacturers, designers and users of gypsum linings with requirements for the application and finishing of such linings in residential and commercial construction applications. This Standard provides a reference for the building industry and specifiers, and a basic Standard for adoption in contracts.
This edition incorporates the following major changes to the previous editions:
(a) Inclusion of surface tolerances.
(b) Cross-reference and alignment to AS/NZS 2311.
Statements expressed in mandatory terms in notes to tables are deemed to be requirements of this Standard.
The terms ‘normative’ and ‘informative’ have been used in this Standard to define the application of the appendix to which they apply. A ‘normative’ appendix is an integral part of a Standard, whereas an ‘informative’ appendix is only for information and guidance.
Originated as AS 2589-1983 and in part as AS CA20-1950. Previous edition AS/NZS 2589:2007. Second edition 2017. Reissued incorporating Amendment No. 1 (November 2018). Reissued incorporating Amendment No. 2 (April 2021).Contents:
Section 1: Scope And General
Section 2: Materials
Section 3: Design Requirements
Section 4: Installation
Appendix A: Measuring The Moisture Content Of Timber Framing
Appendix B: Decoration
Appendix C: Visible Sag In Ceilings
Appendix D: Design Considerations
Appendix E: Possible Cause Of Uneven Linings
Appendix F Partial Sheet Replacement
Interior Board Lining.
BD-011
Association of Wall and Ceiling Industries of Australia; Association of Wall and Ceiling Industries of New Zealand; Australian Chamber of Commerce and Industry; Australian Paint Manufacturers’ Federation; Gypsum Board Manufacturers of Australasia; Housing Industry Association; Master Builders; South Australian Housing Trust.