AS/NZS 2845.3:2020 Water supply - Backflow prevention devices, Part 3: Field testing and maintenance of testable devices
Standards Australia/Standards New Zealand
Supersedes: AS 2845.3-2010 Water supply - Backflow prevention devices, Part 3: Field testing and maintenance of testable devices
Supersedes: AS 2845.3-2010 AMDT 1 Water supply - Backflow prevention devices, Part 3: Field testing and maintenance of testable devices
Draft Designation: DR AS/NZS 2845.3:2018The objective of this Standard is to outline minimum requirements for the testing and maintenance of testable backflow prevention devices in the field.
This Standard is to be read in conjunction with the requirements of the relevant regulatory authority, and the manufacturer’s instructions. The safety practices to be followed while performing field testing and maintenance work should comply with the applicable WH&S legislation and the relevant regulatory authority’s procedures. The actions stipulated within this Standard are in addition to those requirements.
The terms “normative” and “informative” are used in Standards to define the application of the appendices to which they apply. A “normative” appendix is an integral part of a Standard, whereas an “informative” appendix is only for information and guidance.
First published as AS 2845.3-1993. Previous edition 2010. Revised and redesignated as AS/NZS 2845.3:2020.
Contents:
Preface
Section 1: Scope And General
Section 2: Field Testing And Maintenance
Appendix A: (Normative) Field Testing Of Registered Air Gaps And Registered Break Tanks
Appendix B: (Informative) Test Kit Arrangement For Mechanical Backflow Prevention Devices
Appendix C: (Normative) Field Testing Of Pressure-Type Vacuum-Breaker Backflow Prevention Device
Appendix D: (Normative) Spill Resistant Pressure Vacuum-Breaker
Appendix E: (Normative) Field Testing Of Reduced-Pressure-Zone Backflow Prevention Device
Appendix F: (Normative) Field Testing Of Double Check Valve Backflow Prevention Device
Appendix G: (Normative) Field Testing Of Reduced-Pressure-Detector Assembly Backflow Prevention Device
Appendix H: (Normative) Field Testing Of Double Check Detector Assembly Backflow Prevention Device
Appendix I: (Normative) Field Testing Of Single Check Valve (Testable) Backflow Prevention Device
Appendix J: (Normative) Field Testing Of Single Check Valve Detector Assembly Testable Backflow Prevention Devices
Appendix K: (Normative) Field Testing Of Atmospheric Vacuum Breaker Backflow Prevention Devices
Appendix L: (Informative) Example Of Format For Reporting Test Results For Registered Air Gaps And Registered Break Tanks
Appendix M: (Informative) Example Of Format For Reporting Inspection And Maintenance For Backflow Prevention Devices
Backflow Prevention Devices For Water Supply.
WS-023
Australian Building Codes Board; Australian Chamber of Commerce and Industry; Australian Industry Group; Backflow Prevention Association of Australia; Department for Manufacturing, Innovation, Trade, Resources and Energy, SA; Environment and Planning Directorate, ACT; Master Plumbers Australia; Master Plumbers, Gasfitters and Drainlayers New Zealand; NSW Fair Trading; Plastics Industry Pipe Association of Australia; Plumbing Products Industry Group; Queensland Brassware Association; Victorian Building Authority; Water New Zealand; Water Services Association of Australia.