AS 2118.1:2017 Automatic fire sprinkler systems, Part 1: General systems 2017 cover

Publisher
Standards Australia

Version:  Fourth Edition 2017.  (Current)
Short Description
Specifies general requirements for the design, installation and commissioning of automatic fire sprinkler systems in buildings.
AS 2419.1:2021 Fire hydrant installations, Part 1: System design, installation and commissioning 2021 cover

Publisher
Standards Australia

Version:  Sixth Edition 2021.  (Current)
Short Description
Specifies requirements for the design, installation and commissioning and testing of fire hydrant installations that are used for the protection of buildings, structures, storage yards, marinas and associated moored vessels, wharves, and plant.
AS 1768:2021 Lightning protection 2021 cover

Publisher
Standards Australia

Version:  Sixth Edition 2021.  (Current)
Short Description
Specifies requirements for the design, installation, maintenance and testing of lightning protection on common structures, and for electrical and electronic systems within those structures for the protection of people and property from the hazards of lightning.
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location 2001 cover

Publisher
Standards Australia

Version:  Sixth Edition 2001.  (Current)
Short Description
Specifies the criteria for the selection of portable fire extinguishers and the requirements for their application, location and distribution.
AS/NZS 3001.2:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 2: Connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Specifies requirements for electrical installations associated with connectable electrical installations used for the purposes of accommodation, habitation or other residential, commercial purposes or recreational uses that are intended for connection to external low voltage a.c. supply systems (i.e. 50 V a.c. to 1000 V a.c.) by either a detachable supply lead or a supply lead directly connected to the connectable electrical installation; includes requirements and provides guidance for the installation of extra-low voltage systems (i.e. less than 50 V a.c. or 120 V d.c. ripple free).
AS/NZS 3000:2018 Electrical installations (known as the Australian/New Zealand Wiring Rules) 2018 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2018.  (Current)
Short Description
AS NZS 3000 2018 (known as the Australian/New Zealand Wiring Rules) specifies requirements for the design, construction and verification of electrical installations, including the selection and installation of electrical equipment forming part of such electrical installations; part 1 provides provisions that constitute the minimum regulatory requirements for a safe electrical installation; part 2 provides work methods and installation practices that are ‘deemed to comply’ with the requirements of Part 1.
AS 2118.8-1997 Automatic fire sprinkler systems, Part 8: Minor modifications 1997 cover

Publisher
Standards Australia

Version:  First Edition 1997.  (Current)
Short Description
Sets out requirements covering minor modifications to existing sprinkler systems of light or ordinary hazard classification, such as the removal, alteration or addition of sprinklers, or the modification or addition of ranges and distribution pipes of limited size.
AS/NZS 3001.1:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 1: Site supplies for connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Sets out requirements for electrical installations associated with site supplies for connectable electrical installations that are intended for connection to low voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).
AS/NZS 3004.2:2014 Electrical installations - Marinas and boats, Part 2: Boat installations 2014 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2014.  (Pending Revision)
Short Description
Specifies requirements for the design, construction and installation of electrical systems in boats that have a length of up to 50 m, and are designed for use on inland waters or at sea.