AS 2118/4118

This series groups together the current parts to Australian Standard, AS 2118 Automatic fire sprinkler systems, and; AS 4118 Fire sprinkler systems, available in the BIG library.

The AS 2118 and AS 4118 series are Australian standards that provide guidelines for the design, installation, and maintenance of fire sprinkler systems. 

- AS 2118 covers the general requirements for automatic fire sprinkler systems in buildings. It includes guidelines for system design, installation, and maintenance to ensure that sprinkler systems effectively control or extinguish fires and protect property and lives.

- AS 4118 focuses on specific requirements for fire sprinkler systems used in high-risk and specialised applications, such as hazardous areas or large-scale industrial facilities. It provides detailed criteria for the design and performance of these systems to address unique fire protection challenges.

Together, these standards ensure that fire sprinkler systems are appropriately designed and maintained to provide reliable fire protection in various types of buildings and environments, helping to enhance safety and minimise damage in the event of a fire.


Current Standards

Specifies requirements for the design, installation and commissioning of wall wetting sprinkler systems where the exposure protection requirements of AS 2118.1 do not apply; intended to provide automatic external and/or internal protection to the unprotected infills of a building.
Sets out the requirements for the design and installation of deluge fire sprinkler systems to protect hazardous installations in buildings.
Specifies requirements for the design, installation and acceptance testing (commissioning) of automatic fire sprinkler systems in accommodation buildings not more than four storeys.
Specifies requirements for the design, installation, commissioning and maintenance of automatic fire sprinkler systems for one and two family homes.
Sets out requirements covering minor modifications to existing sprinkler systems of light or ordinary hazard classification, such as the removal, alteration or addition of sprinklers, or the modification or addition of ranges and distribution pipes of limited size.
Specifies requirements for the information to be provided for the approval of fire sprinkler systems in accordance with AS 2118.1 and wall wetting sprinkler systems in accordance with AS 2118.2.
Sets out minimum criteria for the design, installation and commissioning of combined sprinkler and hydrant systems (including fire hose reels where appropriate) in multistorey buildings greater than two storeys in height.
Specifies the performance and testing of metallic element and frangible glass bulb sprinklers and sprayers.
Specifies the requirements for the construction and performance of alarm valves (wet), for use in fire sprinkler systems.