AS 1768:2021 Lightning protection 2021 cover

Publisher
Standards Australia

Version:  Sixth Edition 2021.  (Current)
Short Description
Specifies requirements for the design, installation, maintenance and testing of lightning protection on common structures, and for electrical and electronic systems within those structures for the protection of people and property from the hazards of lightning.
AS 1576.6:2020 Scaffolding, Part 6: Metal tube-and-coupler scaffolding - Deemed to conform to AS/NZS 1576.1 2020 cover

Publisher
Standards Australia

Version:  First Edition 2020.  (Current)
Short Description
The objective of this Standard is to provide tabulated geometrical limits and guidance which, when applied to tube and coupler installations, would ensure conformance to requirements of AS/NZS 1576.1.
AS/NZS 1576.4:2013 Scaffolding, Part 4: Suspended scaffolding 2013 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2013.  (Current)
Short Description
Provides manufacturers and suppliers of suspended scaffolds and accessories with requirements to ensure the proper operation of suspended scaffolds.
AS/NZS 1576.1:2019 Scaffolding, Part 1: General requirements 2019 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2019.  (Current)
Short Description
Sets out design and operational requirements for scaffolding systems, scaffolding equipment and scaffolds. It includes specifications for catch platforms erected on scaffolds and covers temporary stairways for use on a general construction site.
AS/NZS 3001.2:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 2: Connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Specifies requirements for electrical installations associated with connectable electrical installations used for the purposes of accommodation, habitation or other residential, commercial purposes or recreational uses that are intended for connection to external low voltage a.c. supply systems (i.e. 50 V a.c. to 1000 V a.c.) by either a detachable supply lead or a supply lead directly connected to the connectable electrical installation; includes requirements and provides guidance for the installation of extra-low voltage systems (i.e. less than 50 V a.c. or 120 V d.c. ripple free).
AS/NZS 3000:2018 Electrical installations (known as the Australian/New Zealand Wiring Rules) 2018 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2018.  (Current)
Short Description
AS NZS 3000 2018 (known as the Australian/New Zealand Wiring Rules) specifies requirements for the design, construction and verification of electrical installations, including the selection and installation of electrical equipment forming part of such electrical installations; part 1 provides provisions that constitute the minimum regulatory requirements for a safe electrical installation; part 2 provides work methods and installation practices that are ‘deemed to comply’ with the requirements of Part 1.
AS/NZS 4994.4:2018 Temporary edge protection, Part 4: Perimeter Protection Screens 2018 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2018.  (Current)
Short Description
Sets out the requirements for the design, manufacture, installation,re-positioning and dismantling of perimeter protection screens, of height 1 m and above, that are to be attached to formwork or to a permanent structure to provide edge protection for personnel and minimise falling objects during construction.
AS/NZS 3001.1:2022 Electrical installations - Connectable electrical installations and supply arrangements, Part 1: Site supplies for connectable electrical installations 2022 cover

Publisher
Standards Australia/Standards New Zealand

Version:  First Edition 2022.  (Current)
Short Description
Sets out requirements for electrical installations associated with site supplies for connectable electrical installations that are intended for connection to low voltage a.c. supply systems (i.e. exceeding 50 V a.c. but not exceeding 1 000 V a.c.).
AS/NZS 4994.3:2023 Temporary edge protection, Part 3: Installation and dismantling for edges other than roof edges 2023 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Second Edition 2023.  (Current)
Short Description
AS/NZS 4994.3:2023 specifies requirements and gives guidance for the selection and installation of edge protection conforming to AS/NZS 4994.1, for persons working near an opening in a floor, or near a platform edge or floor edge prior to the installation of the permanent walling materials.
AS/NZS 4994.2:2023 Temporary edge protection, Part 2: Roof edge protection - Installation and dismantling 2023 cover

Publisher
Standards Australia/Standards New Zealand

Version:  Third Edition 2023.  (Current)
Short Description
AS/NZS 4994.2:2023 specifies requirements and give guidance for the selection, installation, use and dismantling of roof edge protection conforming to AS/NZS 4994.1. It covers temporary roof edge protection for persons working on roofs of buildings having roof slopes of not greater than 35° to the horizontal