Skip to main content

Search all content

181 - 190 of 244 results
AS 1289.6.3.3-1997 Methods of testing soils for engineering purposes, Method 6.3.3: Soil strength and consolidation tests - Determination of the penetration resistance of a soil - Perth sand penetrometer test 1997 cover

Publisher
Standards Australia

Version:  First Edition 1997.  (Current)
Short Description
Sets out the procedure for determining the resistance of a soil to penetration by a flat ended rod of 16 ±0.2 mm diameter driven with a 9 kg mass, dropping 600 mm; use of the method is limited to granular soils with a maximum particle size not exceeding 2 mm, and a layer thickness of at least of 450 mm.
AS 4055:2021 Amd 1:2024 Wind loads for housing 2024 cover

Publisher
Standards Australia

Version:  Fourth Edition 2024.  (Current)
Short Description
AS 4055:2021 is amended as follows. The amendments should be inserted in the locations as instructed.
AS 4200.2:2017 Pliable building membranes and underlays, Part 2: Installation 2017 cover

Publisher
Standards Australia

Version:  Third Edition 2017.  (Pending Revision)
Short Description
Sets out requirements for the installation of pliable building membranes (also known as ‘sarking’ or ‘underlay’), when used either independently or as a facing to other materials, such as insulation materials, for water control, thermal control, vapour control or air control, or a combination of these control functions.
AS 1860.2-2006 Particleboard flooring, Part 2: Installation 2006 cover

Publisher
Standards Australia

Version:  First Edition 2006.  (Pending Revision)
Short Description
Proposes procedures for the selection, placement and fixing of Class 1 particleboard flooring complying with AS/NZS 1860.1.
AS 4200.1:2017 Pliable building membranes and underlays, Part 1: Materials 2017 cover

Publisher
Standards Australia

Version:  Second Edition 2017.  (Pending Revision)
Short Description
Sets out requirements for materials for use as pliable building membranes (also known as sarking or underlay), when used either independently or as a facing to other materials, such as insulation materials, and as control functions for water, thermal vapour or air control.
AS 1684.3-2010 Residential timber-framed construction, Part 3: Cyclonic areas 2010 cover

Publisher
Standards Australia

Version:  Third Edition 2010.  (Available Superseded)
Short Description
Provides the building industry with procedures that can be used to determine building practice, to design or check construction details, and to determine member sizes, and bracing and fixing requirements for timber-framed construction in cyclonic areas.
AS 4100-1998 Steel structures 1998 cover

Publisher
Standards Australia

Version:  Second Edition 1998.  (Available Superseded)
Short Description
Sets out minimum requirements for the design, fabrication, erection, and modification of steelwork in structures in accordance with the limit states design method
AS 1735.12-1999 Lifts, escalators and moving walks, Part 12: Facilities for persons with disabilities 1999 cover

Publisher
Standards Australia

Version:  Third Edition 1999.  (Available Superseded)
Short Description
Sets out requirements for passenger lifts which are specifically designed to assist persons with disabilities.
AS 1720.4-2006 Timber structures, Part 4: Fire resistance for structural adequacy of timber members 2006 cover

Publisher
Standards Australia

Version:  Second Edition 2006.  (Available Superseded)
Short Description
Provides a computational method for determining the fire resistance of solid and glued-laminated structural timber members (for the purpose of structural adequacy) as an alternative to the test method specified in AS 1530.4.